FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  460    461    462    463    464  465  466    467    468    469    470  
img
.
DRAFT
TM 5-4210-249-13&P-1
0094
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03705
NOTE
Foam agent and water may leak from system when foam system inlet check valve is
removed from vehicle. Place suitable container or drain pan under check valve and
eductor before performing Step 6.
Step 6.
Turn battery disconnect switch to OFF position (WP 0007). Remove foam system inlet
check valve (WP 0290). Check if foam system inlet check valve is free from blockage
and damage.
a.
If foam system inlet check valve is blocked or damaged, remove
blockage or replace damaged foam system inlet check
valve (WP 0290).
b.
If foam system inlet check valve is not blocked or damaged, replace
eductor valve (WP 0287).