img
. . .
DRAFT
TM 5-4210-249-13&P-1
0076
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03721
Step 3.
Turn battery disconnect switch to OFF position (WP 0007). Open pump operator's
panel (WP 0019). While an assistant puts pump operator's panel START PUMP
ENGINE STOP switch to START position (WP 0004), check for continuity across pump
operator's panel START PUMP ENGINE STOP switch from terminal wire 4072 (green)
to terminal wire 4070 (white).
If there is no continuity, replace pump operator's panel START PUMP
ENGINE STOP switch (WP 0330).
0076-3