TM 5-4210-233-14&P-1 5-16.  FUEL PUMP-Continued WARNING Adhesives,  solvents,  and  sealing  compounds  can burn  easily,  can  give  off  harmful  vapors,  and  are harmful  to  skin  and  clothing.    To  avoid  injury  or death,  keep  away  from  open  fire  and  use  in  well- ventilated  area.    If  adhesive,  solvent,  or  sealing compound gets on skin or clothing, wash immediately with soap and water. (4) Apply adhesive-sealant (Item 35, Appendix E) to three screws (6). (5) Install three screws (6). (6) Install two fuel hoses (7). Follow-on Maintenance. (1) Install thermostat crossover tube (see para 4-137). (2) Install DDEC Electronic Control Module (see para 5-28). (3) Connect batteries (see para 4-114.) 5-95