TM 5-4210-233-14&P-1
Table 2-1. Operator PMCS Procedures -Continued
Item
Interval
Equipment Is Not
No.
A
D
W
ITEM TO BE INSPECTED/Procedures
Ready/Available If:
6
CAB ASSEMBLY, LIGHTS AND CONTROLS -
Contlnued
Cab Door Glass, Windshield
Check window regulators move windows up and
down smoothly. Be sure windows are unbroken.
Ensure all seals are in place.
Cab Mirrors
Check mirrors are not cracked and mounting is
secure.
Cab Lights
Check all lamps function:
- Any driving lights are
Headlights
inoperable.
Marker Lights
Turn Signal Lights
Warning Lights
Roof Beacon Light
Cab Dome Lights
Cab Step Lights
Check both cab spotlights illuminate. Swivel handle
and check that lamp swivels smoothly to extent of its
travel.
Siren and PA System
Check operation of the siren/PA unit mounted in the
- Siren/PA unit does not
cab.
operate in one or more of
its functions.
Check siren, radio rebroadcast and PA functions.
Back-up Alarm
Check operation of back-up alarm with main engine
running and shift lever in reverse.
2-35
|