TM 5-4210-233-14&P-1
Table 2-1. Operator PMCS Procedures -Continued
Item
Interval
Equipment Is Not
No.
A
D
W
ITEM TO BE INSPECTED/Procedures
Ready/Available If:
5
HOSE BODY ASSEMBLY - Contlnued
Rear Roll-Up Door
Check that rear roll-up door operates smoothly,
without binding.
Check compartment to see that equipment is stowed
- Equipment stowing
correctly and fixtures are in place.
fixtures missing or
loose.
Inspect ladder keeper door for missing attaching
- Ladder keeper door
hardware or looseness. Report loose keeper door or
missing or will not latch
missing attaching hardware to Unit Maintenance.
securely.
Air Bottle Rack and Slide Tray
Check that locking pin and locking pin retainer chain
are in place.
Check that slide tray works smoothly, and slide locks
function properly.
Inspect air bottle rack for visible damage.
Report any deficiencies to Unit Maintenance.
6
CAB ASSEMBLY, LIGHTS AND CONTROLS
Cab Roof Panel
Check that attaching hardware is in place, panel is
- Attaching hardware
not severely bent, scratched, or damaged. Check
totally missing.
inside of cab for signs of water leakage.
Cab Doors
Ensure both cab doors latch. Check inner and outer
- Cab door will not latch.
handles operate.
Be sure door seals are in place.
2-34
|