TM 5-4210-233-14&P-1
5-14. STARTER REPAIR AND TESTING - Continued
(4)
Remove three screws (7) to disconnect three field leads (8) from brush holder (9).
(5)
Remove six screws (10), end cap (1), and brush holder (9).
NOTE
Armature may stay with end cap or in field frame.
(6)
Remove armature (11).
(7)
Remove preformed packing (12) from end cap (1).
(8)
Remove washer (13) and thrust washer (14 from armature (11).
)
WARNING
Death or serious injury could occur if compressed air is directed
against the skin. Do not use compressed air for cleaning or
drying unless the pressure is/has been reduced to 30 psi (2.11
kg/cm2) or less. When working with compressed air, always use
chip guards eye protection and other personal protective
equipment.