TM 10-4210-235-13
e.
Installation (See figure 4-25.)
(1)
Place tank lifting tool (9) onto tank (1) fill collar. Install cap (10).
WARNING
Tank can swing while suspended from a lifting device causing injury to personnel
and/or damage to equipment
CAUTION
Piping is exposed extending outside of tank and can be damaged when lifting.
(2)
Attach lifting device to tank lifting tool (9). Secure tank (1) from swinging and carefully lift. Lower tank
onto unit while aligning mounting holes.
(3)
Remove cap (10) and tank lifting tool (9).
(4)
Install rod (3) and new spring pin (2).
(5)
Install four flat washers (8), screws (7), new lock washers (6), and nuts (5).
(6)
Install discharge hose and charging hose per paragraph 4-18, (4) and (8).
(7)
Install AFFF tank heater assembly per paragraph 4-23.
(8)
Fill tank (1) with AFFF solution per paragraph 2-10.
(9)
Release parking brakes and raise jacks, per paragraph 4-29, if moving equipment.
4-61
|