VENT/WINDOW RUN CHANNEL REPLACEMENT.
Up
TM-5-4210-224-14-P 250 6PM Mini-Pumper Firefighting Truck Model No.:CM-KFT-3 Manual
Next
DOOR WINDOW REPLACEMENT.
TM 5-4210-224-14&P
4-173. VENT/WINDOW RUN CHANNEL REPLACEMENT (Continued).
INSTALLATION
a. Position the door vent/window run channel
assembly (2) and install to the vehicle by
rotating the vent assembly into the door and
fitting it into the door frame.
b. Install the door to ventilator screws (4) and
spacers (5) starting with the screw at the top of
the door and working downward. c. Install the
door panel to run channel bolts (3).
d. Install the run channel molding (1) by seating the
clip into the vent, then pushing the remainder of
the molding into the run channel.
e. Install the door trim panel (paragraph 4-176).
f. Check operation of the window assembly.