TM-5-4210-220-12 Truck Firefighting: Powered Pumper: Foam and Water 500-GPM Capacity; Centrifugal Pump Power Takeoff Driven Manual
Next
WINTERIZATION SYSTEM - TM-5-4210-220-12_103
TM 5-4210-220-12 Table 2-1.  Operator Preventive Maintenance checks and Services (PMCS) - Continued A - After Mission D - Daily Checks W - Weekly Interval Item ITEM TO BE INSPECTED/Procedure Equipment is not No. A D W Ready/Available If 31 FOAM TANK INSPECTION With foam tank empty, open foam tank inspection - Tank leaks. hatch Look for any signs of corrosion/leaks. 32 WATER TANK INSPECTION With water tank empty, open water tank inspection - Tank leaks. hatch.  Look for any sign of corrosion or leaks. Start main engine and connect rear fill valve to pressurized water supply. Set control switch to ON and check water tank starts to fill.  Set control switch to OFF and check valve closes.  Listen for water splashing inside of tank.  If valve leaks report to Organizational Maintenance. Close hatch and remove hose connection to tank rear fill valve. 2-34