TM 9-4931-363-14&P
Test set indications
Operation of test set controls
POWER indicator lights
1
Set POWER switch to ON-60 Hz or ON-400
Hz.
PHASE and multimeter indications are as shown below for respective
2 Set TEST SELECT switch to 2, METER
positions of the EIA/AMPL switch. The multimeter readings for switch
SELECT switch to 1, and RSLVR SELECT
positions 5 through 10 should be as calculated in Chapter 4, Section VI.
switch to R2. Set multimeter range switch to
Perform the adjustments specified to obtain the values of V5 through
10 and function to AC V.
V10.
Multimeter
EIA/AMPL
PHASE
position
indication
indication
0
10.6 0.6 (V1)
1
10.6 0.6 (V2)
180
2
5.3 0.3 (V3)
0
3
5.3 0.3 (V4)
180
4
V5
0
5
180
V8
6
180
V9
7
Vl0
0
8
0
V7
9
V6
0
10
Multimeter indicates 30 3 volts
3 Set multimeter range switch to 100 and
function to DC V. Set METER SELECT
switch to 5, CARD switch to 2, and
LINKAGE switch to 1.
4 Set CARD switch to 1.
Multimeter indications are as follows for respective positions of
LINKAGE switch.
LINKAGE
Multimeter
position
indication
+18 l
1
-18 1
2
3
+12 0.7
4
-6 0.36
+5 0.30
5
Multimeter indicates -8 0.48
5 Set CARD switch to 2 and LINKAGE switch
to 2.
|