TEST AND INSPECTION - Continued
Correction Counter Setting and Excursion Range Inspection - Continued
4
6
5
1 fc 6 8 4
3.
Turn correction knob (5) clockwise as far as possible. Check that correction counter (6) reads on or
between R-95 and R-99.
Check that vertical reticle line (3) is centered on collimator reticle target within 0.1 mil.
4.
5.
Turn correction knob (5) counterclockwise as far as possible. Check that correction counter (6) reads on
or between L-95 and L-99.
6.
Repeat step 4.
7.
Turn correction knob (5) to set correction counter (6) at 00.
Checking Effect of Correction Counter Setting on Deflection Counter
1
2
3
1 fc 6 8 5
1.
Record reading on deflection counter (1) closest to 0.25 mil.
2.
Turn correction knob (2) until correction counter (3) reads R-95.
0100 00-28
|