TM 9-1240-375-34&P
0098 00
CLEANING
WARNING
Use cleaning compound in well-ventilated area away from open flame. Cleaning
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever cleaning compound is used.
Remove rust, corrosion, dirt, and grease from metal parts. Remove dirt and grease using cleaning compound
(item 10, WP 0152 00).
NOTE
General procedures for cleaning metal parts and optics, removing corrosion, staking
pins, and other procedures are contained in TM 9-254.
REPAIR OR REPLACEMENT
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0141 00.
ASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M137 only).
1.
If removed, install two headless straight pins (1) in bottom of counter box assembly (2). If headless
straight pins are loose, ream holes for next larger standard size headless straight pins and install
(M137 only).
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
2.
Apply sealing compound (item 13, WP 0152 00) to threads of four machine screws (3) (M137 only).
3.
Position stop plate (4) on counter box assembly (2) and secure in place with four new lockwashers (5)
(item 15, WP 0141 00) and four machine screws (3) (M137 only).
0098 00-4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |