TM 9-1240-375-34&P
0082 00
5
7
9
6
1
1 fc 5 4 3
8
1 fc 5 4 4
3.
Position mounting bracket (5) on M172/M172A1 mount (1).
4.
Install four bolts (6) to secure mounting bracket (5) to M172/M172A1 mount (1).
5.
Place plate-mounted level (7) parallel to block (8) of shaft on optical equipment test fixture (9).
11
9
11
7
8
10
1 fc 5 4 5
12
1 fc 5 4 6
6.
Turn cant handwheel (10) until bubble (11) in plate-mounted level (7) centers.
7.
Place plate-mounted level (7) 90 degrees to block (8) on optical equipment test fixture (9).
8.
Turn elevation handwheel (12) until bubble (11) in plate-mounted level (7) centers.
0082 00-5
|