TM 9-1240-375-34&P
0073 00
TEST AND INSPECTION - Continued
Setting Up and Adjusting the Cross-Leveling Fixture - Continued
10
9
8
11
12
1 fc 4 1 4
7.
Install four lockwashers (9), four screws (10), four posts (11), and two plates (12) on adapter plate (8).
Tighten screws.
1
13
14
1 fc 4 1 5
8.
Place precision level (13) on block (14), perpendicular to axis of rotation.
9.
Level the cross-leveling fixture (1) in both cant and elevation.
NOTE
When installing test fixture adapter (2), ensure adapter keys (15) are parallel to top
of block within 0.1 mil.