TM 9-1240-375-34&P
GENERAL SUPPORT
M171/M171A1 TELESCOPE AND QUADRANT MOUNT
(1240-01-039-7273/1240-01-515-8265)
OPTICAL INSTRUMENT ROCKER ASSEMBLY MAINTENANCE
DISASSEMBLY, CLEANING, REPAIR OR REPLACEMENT, ASSEMBLY
INITIAL SETUP:
Tools and Special Tools
Shop Set, Instrument and Fire Control: Field Maintenance, Basic Less Power (SC 4931-95-A07)
Tool Kit, Electronic System Maintenance (SC 5180-95-B29)
Torque adapter (item 19, WP 0149 00)
Materials/Parts
Grease (item 15, WP 0152 00)
Sealing compound (item 13, WP 0152 00)
Solvent cleaning compound (item 12, WP 0152 00)
Wiping rag (item 18, WP 0152 00)
References
DISASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary.
WARNING
When maintaining battery illuminated fire control equipment follow battery
warnings in warning summary.
0067 00-1
|