TM 9-1240-375-34&P
0064 00
ASSEMBLY
4
3
2
1
1 fc 2 8 9
1.
Position optical instrument mirror (1) on bearing housing assembly (2).
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
2.
Apply sealing compound (item 13, WP 0152 00) to threads of two machine screws (3). Wipe off excess
sealing compound with a clean wiping rag (item 18, WP 0152 00). Install two new lockwashers (4)
(item 9, WP 0126 00) and two machine screws. Tighten machine screws.
END OF WORK PACKAGE