TM 9-1240-375-34&P
0064 00
DISASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M171 only).
3
2
1
4
1 fc 2 8 8
Remove two machine screws (1), two lockwashers (2), and optical instrument mirror (3) from bearing
housing assembly (4). Discard lockwashers.
REPAIR OR REPLACEMENT
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0126 00.
0064 00-2
|