Click here to make tpub.com your Home Page

Page Title: Checking the Effect of the Correction Counter Setting on the Elevation Counter and Level Bubble
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-1240-375-34&P
0057 00
10.
Set fire control quadrant (13) to 200 mils. Place on top of mounting bracket (1) and zero using
micrometer knob (14).
NOTE
Micrometer dial will indicate any error. Error should not exceed 0.5 mil (1.0-mil total
spread).
11.
Repeat steps 1 through 10 with fire control quadrant set at elevations of 400, 600, 800, 1000, 1200, and
1400 mils. Error should not exceed 0.5 mil.
Checking the Effect of the Correction Counter Setting on the Elevation Counter and Level Bubble
2
3
4
5
1
1 fc 2 6 2
1.
Mount M17/M18 or M17A1/M18A1 quadrant (1) on optical equipment test fixture (2). Refer to
Mounting M17/M18 or M17A1/M18A1 Quadrant on Optical Equipment Test Fixture.
NOTE
Observe bubble in elevation level (3) during steps 2 through 5. It must remain
centered within one vial graduation.
2.
Turn correction knob (4) clockwise to -50 mils.
Check that elevation counter (5) reads 50 0.5 mils.
3.
4.
Turn correction knob (4) counterclockwise to 50 mils.
Check that elevation counter (5) reads 9950 0.5 mils.
5.
0057 00-15