Table 1. Troubleshooting Procedures.
NOTE
The following steps apply to both the M138 and M138A1 elbow telescopes.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1
1 fc 0 5 0
1. OPTICAL INSTRUMENT
1. Check for incorrectly
Reassemble optical instrument
LATCH SET (1) DOES NOT
assembled optical instrument
latch set correctly (WP 0104 00).
OPERATE CORRECTLY.
latch set.
2. Check for worn, damaged, or
Replace parts (WP 0104 00) as
missing parts.
required and authorized.
END OF WORK PACKAGE