TM 9-1240-375-34&P
GENERAL SUPPORT
M137/M137A2/M137A3 PANORAMIC TELESCOPE
(1240-01-038-0531/1240-01-483-6103/1240-01-483-6100)
TROUBLESHOOTING PROCEDURES
OPTICAL ELEMENTS
INITIAL SETUP:
References
OPTICAL ELEMENTS
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. INTERNAL OPTICS ARE
1. Inspect seal between head
1. Replace defective seal (WP
FOGGED OR HAVE
assembly and body assembly.
2. Replace defective seal (WP
2. Inspect seal between body
assembly and elbow assembly.
3. Inspect seal in head assembly
3. Replace defective seal (WP
between cover assembly and
window.
END OF WORK PACKAGE
0040 00-1/2 blank
|