TM 55-1925-292-14&P
0040 00
CLEANING AND INSPECTION
WARNING
Cleaning solvent is flammable and its vapor is potentially explosive. Do not use
cleaning solvent in the vicinity of spark, open flame, or excessive heat. Do not
use cleaning solvent in unventilated spaces. Failure to follow these precautions
can result in death or serious injury.
1. Clean all metal parts with dry cleaning solvent and allow to air dry.
2. Check for binding, scoring, or burrs on the relief valve faceplate bushing (figure 1, item 19), the flange
bushings (figure 1, item 36), the bearing (figure 1, item 26), and all other removed parts. Inspect all compo-
nent parts for unusual wear or damage and replace as required.
WARNING
Do not exceed 25 PSI (1.7 bar) nozzle pressure when using compressed air to dry
parts. Wear goggles for eye protection. Do not direct air stream toward self or
other personnel. Failure to comply with this warning may cause severe injury to
personnel.
3. Direct a stream of compressed air at the relief valve faceplate bushing (figure 1, item 19), the flange bushings
(figure 1, item 36), and the bearing (figure 1, item 26) to remove any debris.
ASSEMBLY
1. Install the flange bushings (figure 1, item 36) in the back plate assembly (figure 1, item 22).
2. Install the relief valve faceplate bushings (figure 1, item 19) in the relief valve faceplate (figure 1, item 9).
3. Install a new gasket (figure 1, item 32) on the back plate assembly (figure 1, item 22).
4. Install the case (figure 1, item 18) on the back plate assembly (figure 1, item 22).
5. Install the drive gear (figure 1, item 33) on the drive shaft (figure 1, item 30) and secure it with the key
(figure 1, item 35).
6. Install the drive shaft (figure 1, item 30) in the case (figure 1, item 18).
0040 00-4
|