Page Title: TYPICAL BALL VALVE REPAIR
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-1925-292-14&P
0016 00
TYPICAL BALL VALVE REPAIR
DISASSEMBLY
1. Perform the Typical Flanged Ball Valve Removal procedure in this work package.
2. Remove the lever nut (figure 6, item 1) and the handle (figure 6, item 2) from the valve body (figure 6, item 3).
3. Remove the packing gland (figure 6, item 4) and the valve stem packing (figure 6, item 5) from the valve body
(figure 6, item 3). Discard the valve stem packing.
4. Remove the valve stem (figure 6, item 6) and the valve stem bearing (figure 6, item 7) from the valve body
(figure 6, item 3).
5. Remove the retainer (figure 6, item 8) from the valve body (figure 6, item 3).
1
2
4
5
6
7
12
11
10
9
8
3
Figure 6. Typical Flanged Globe Stop Check Valve