TM 55-1925-292-14&P
0016 00
1
4
4
2
6
5
3
3
5
6 2
Figure 5. Typical Flanged Globe Stop Check Valve
INSTALLATION
WARNING
Do not allow cleaning solvents to come in contact with unprotected skin or eyes.
Prolonged skin contact can cause illness or injury. Eye contact can cause seri-
ous injury. Always wear chemical protective gloves and goggles when handling
hydraulic fluid, engine oil, and cleaning solvents. Failure to follow these precau-
tions can result in illness or serious injury.
Removing components by means of wire brushing produces flying particles. These
particles can cause serious injury to personnel. Protective goggles, gloves, and
long sleeves must be worn at all times during wire brushing operations. Failure
to comply with this warning can result in serious injury to personnel.
1. Using a wire brush and dry cleaning solvent, clean the piping flanges (figure 5, item 6) and valve flanges
(figure 5, item 5).
2. Install two new gaskets (figure 5, item 4) on the piping flanges (figure 5, item 6).
3. Install the valve (figure 5, item 1) and secure it with the eight bolts (figure 5, item 4) and the eight nuts
(figure 5, item 3).
5. Perform the Follow-On Service procedure at the end of this work package.
0016 00-9
|