TM 55-1925-292-14&P
UNIT MAINTENANCE
FIREFIGHTING, FIRE ALARM, AND FIRE SUPPRESSION SYSTEMS FOR
INLAND AND COASTAL LARGE TUG (LT)
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING LUBRICATION
Table 1. Unit Preventive Maintenance Checks and Services
ITEM INTERVAL
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
AFFF PUMP
1
Monthly
0.1
Pump
Use a lubricating gun to lubricate the
pump with two shots of general
purpose grease at the grease fitting.
Refer to table 2 for the proper grease.
GREASE FITTING
FIRE
DETECTION
SYSTEM
2
Semiannual
2.0
Sensors
Test the fire detection system
Any sensor
is inoperative.
GALLEY FIRE
SUPPRESSION
SYSTEM
3
Semiannual
2.0
Certification
Semiannual certification of the
System
system is required. Notify the
certification
maintenance supervisor.
has expired.
0013 00-1
|