TM 55-1925-292-14&P
0005 00
FIRE STATION OPERATION
1. Perform the Pressurize the Fire Main procedure in this work package.
2. Ensure that the fire hose (figure 14, item 1) is connected to the fire station cutoff valve (figure 14, item 2).
2
4
3
1
Figure 14. Fire Station
3. Remove the fire hose (figure 14, item 1) from the hose storage rack (figure 14, item 3).
4. Lay the hose (figure 14, item 1) out and extend it to its full length.
5. Verify that the nozzle valve (figure 14, item 4) is CLOSED.
6. Slowly OPEN the fire station cutoff valve (figure 14, item 2) and pressurize the fire hose.
7. Firmly grasp the fire hose nozzle (figure 14, item 4) and direct it at the base of the fire.
WARNING
When operating a pressurized fire hose, hold the nozzle with a firm grip. If not
held firmly, the nozzle will thrash about and may cause serious injury or death to
personnel.
8. Slowly OPEN the nozzle valve (figure 14, item 4) and direct the water stream at the base of the fire.