TM 55-1925-292-14&P
0002 00
GALLEY FIRE SUPPRESSION SYSTEM
1
D.C.
UP
LOCKER
CREW'S MESS/
DN
RECREATION AREA
BOATSWAIN'S
STORES
GALLEY
2
6
3
MAIN DECK
5
4
Figure 3. Galley Fire Supression System
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS
1. Fire Alarm Pull Station (figure 3, item 1). The manual pull box allows the crew to manually activate the galley
fire suppression system.
2. Fusible Links (figure 3, item 2). These fusible links are activated at 500 F (260 C) and are located over the
solid hot top and flat griddle.
3. Fusible Link (figure 3, item 3). This fusible link is activated at 360 F (182 C) and is located over the deep fat
fryer.
4. Gaylord Washdown System (figure 3, item 4). This system is activated when the galley fire suppression
system is activated.
5. Galley Fire Suppression System (figure 3, item 5). This cabinet houses the galley fire extinguishing agent.
6. Distribution Nozzles (figure 3, item 6). These nozzles deliver the galley fire suppression extinguishing agent
to the galley heat producing equipment.