DRAFT
TM 5-4210-249-13&P-4
0604
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02342
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Firmly insert flat blade screwdriver in square hole to open spring in terminal. When fully
inserted, screwdriver will lock in place and wire can be removed from terminal.
2.
Remove three heat trace cable wires (5), (6), and (7) from terminal (8) (WP 0606).
3.
Remove three wires (9), (10), and (11) from terminal (8).
4.
Remove nut (12) and fitting (13) from junction box (4).
5.
Remove bushing (14) from fitting (13).
6.
Remove nut (15) and fitting (16) from junction box (4).
7.
Remove bushing (17) from fitting (16).
0604-2