• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
HYDRAULIC GENERATOR MOTOR REPLACEMENT - Continued
HYDRAULIC GENERATOR MOTOR REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  165    166    167    168    169  170  171    172    173    174    175  
img
DRAFT
TM 5-4210-249-13&P-4
0591
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02903
12. Remove two fittings (18) and (24) from hydraulic motor (27).
13. Remove key (29) from shaft (30).
14. Remove eight screws (31), manifold assembly (32), and two preformed packings (33) from hydraulic
motor (27). Discard preformed packings.
15. Remove elbow (20) and preformed packing (34) from manifold assembly (32). Discard preformed packing.
16. Remove valve (35), two preformed packings (36) and (37), and backup ring (38) from manifold assembly (32).
Discard preformed packings.
17. Remove elbow (22) and preformed packing (39) from manifold assembly (32). Discard preformed packing.
END OF TASK
INSTALLATION
1.
Install preformed packing (39) and elbow (22) on manifold assembly (32).
2.
Install backup ring (38), two preformed packings (37) and (36), and valve (35) on manifold assembly (32).