GROUND SWEEPS VALVE REPLACEMENT - Continued
PRE-CONNECTS REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  69    70    71    72    73  74  75    76    77    78    79  
img
DRAFT
TM 5-4210-249-13&P-4
0576
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00082
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
2.
Apply sealing compound to two elbows (3) and (4).
3.
Install two air lines (2) and (1) and elbows (4) and (3) on ground sweeps valve (5).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install pump house panel Q (WP 0540)
2.
Install water pump engine air cleaner assembly (WP 0220)
END OF TASK
END OF WORK PACKAGE
0576-3/(4 blank)