SMALL COMPARTMENT DOORS REPLACEMENT - Continued
SMALL COMPARTMENT DOORS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1249    1250    1251    1252    1253  1254  1255    1256    1257    1258    1259  
img
DRAFT
TM 5-4210-249-13&P-3
0551
4.
Remove two nuts (9), lockwashers (10), washers (11), screws (12), and hinge (13) from SCBA tank access
door (1). Discard lockwashers.
5.
Remove seal (14) from SCBA tank access door (1).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
6.
Clean seal (14) residue from access door (1) with mineral spirits.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT2536
7.
Remove screw (15), washer (16), retainer (17), and twist lock (18) from SCBA tank access door (1).
END OF TASK
SCBA TANK ACCESS DOOR/REAR STEP BUZZER ACCESS DOOR INSTALLATION
1.
Install twist lock (18) on SCBA tank access door (1) with retainer (17), washer (16), and screw (15).
2.
Install seal (14) on SCBA tank access door (1).
3.
Install hinge (13) on SCBA tank access door (1) with two screws (12), washers (11), lockwashers (10), and
nuts (9).
4.
Install rubber bumper (8) on SCBA tank access door (1) with screw (7), washer (6), lockwasher (5), and
nut (4).
5.
Install SCBA tank access door (1) on vehicle with two washers (3) and screws (2).