PUMP HOUSE PANELS REPLACEMENT - Continued
PUMP HOUSE PANELS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1180    1181    1182    1183    1184  1185  1186    1187    1188    1189    1190  
img
DRAFT
TM 5-4210-249-13&P-3
0540
PUMP PANEL R REMOVAL
TFFT00242
1.
Open access door (1).
2.
Remove two screws (2), lockwashers (3), washers (4), and clip (5) from pump panel C (6). Discard
lockwashers.
3.
Remove six screws (7), lockwashers (8), washers (9), and pump panel R (10) from vehicle. Discard
lockwashers.
END OF TASK
PUMP PANEL R INSTALLATION
1.
Install pump panel R (10) on vehicle with six washers (9), lockwashers (8), and screws (7).
2.
Install clip (5) on pump panel C (6) with washer (4), lockwasher (3), and screw (2).
3.
Close access door (1).
END OF TASK