WATER VALVE WIRE HARNESS REPLACEMENT - Continued
WATER VALVE WIRE HARNESS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  797    798    799    800    801  802  803    804    805    806    807  
img
DRAFT
TM 5-4210-249-13&P-3
0465
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03591
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Note position and remove cable ties, split looms, and cushion clips as required.
Note routing of wire harness prior to removal to ensure proper installation.
5.
Loosen screw (11) and remove yellow wire (12) from heat relay terminal 30 (13).
6.
Remove nut (14), lockwasher (15), and black wire (16) from ground stud (17). Discard lockwasher.