DRAFT
TM 5-4210-249-13&P-2
0277
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
1.
Apply sealing compound to threads of elbow (10).
2.
Install two elbows (8) and (10) on valve (5).
3.
Install valve (5) on bracket (13) with two washers (12) and screws (11).
4.
Install hose (7) on elbow (8) with hose clamp (6).
5.
Install hose (9) on elbow (10).
NOTE
Valve handle must be installed with stop on valve handle positioned between 90 degree
indent on valve.
6.
Install valve handle (2) on valve (5) with locknut (4).
7.
Turn valve handle (2) clockwise to the closed position.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -