DRAIN VALVE, DRIVER PRE-CONNECT A REPLACEMENT - Continued
DRAIN VALVE, DRIVER PRE-CONNECT A REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  1217    1218    1219    1220    1221  1222  1223    1224    1225    1226    1227  
img
DRAFT
TM 5-4210-249-13&P-2
0270
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Apply sealing compound to threads of elbow (12).
2.
Install two elbows (7) and (12) on valve (4).
3.
Install hose (11) on elbow (12).
4.
Install hose (6) on elbow (7) with hose clamp (5).
5.
Install valve (4) on bracket (10) with two washers (9) and screws (8).
NOTE
Valve handle must be installed with stop on valve handle positioned between 90 degree
indent on valve.
6.
Install valve handle (1) on valve (4) with locknut (3).
7.
Turn valve handle (1) clockwise to the closed position.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -