DRAFT
TM 5-4210-249-13&P-2
0186
Table 1. Preventive Maintenance Checks and Services. (Continued)
Item
Interval
Item To Inspect
Crewmember Procedure
Not Fully Mission
No.
Or Service
Capable if:
24
During
Pump Operator's
Panel Work
Lights
TFFT00119P
a.
Start water pump engine (WP 0022).
b.
Set pump operator's panel light switch to ON
position.
WARNING
ICON 13
Pump operator's panel lights become hot after being on for an extended period of
time. Use extreme care when operating pump operator's panel not to contact
pump operator's panel light. Failure to comply may result in burns to personnel.
c.
Check that side lights illuminate.
25
During
Pump Operator's
Panel Switches
Inspect pump operator's panel switches for proper
operation and visible damage.
26
During
Pump Operator's
Panel Pressure
Governor
Inspect pump operator's panel pressure governor
for proper operation and visible damage.
0186-16