PUMP HOUSE HEATER DOES NOT OPERATE PROPERLY - Continued
PUMP HOUSE HEATER DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  710    711    712    713    714  715  716    717    718    719    720  
img
DRAFT
TM 5-4210-249-13&P-2
0182
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04602
Step 21.
Install circuit breaker P4 (WP 0412). Remove pump house panel G (WP 0540).
Disconnect pump house wire harness pump house heater 3-terminal connector. Turn
battery disconnect switch to ON position (WP 0007). Check for 22 to 28 VDC between
wires 2454 (green) at pump house wire harness pump house heater 3-terminal
connector, terminals A and B, and a known good ground.
a.
If 22 to 28 VDC are not present at both terminals, go to Step 24.
b.
If 22 to 28 VDC are present at one but not both terminals, repair wire
2454 in pump house wire harness if repairable (TM 9-2320-325-14&P),
or replace pump house wire harness (WP 0458).
c.
If 22 to 28 VDC are present at both terminals, go to Step 22.
0182-17