EXTENDABLE FLOODLIGHTS DO NOT OPERATE - Continued
EXTENDABLE FLOODLIGHTS DO NOT OPERATE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  413    414    415    416    417  418  419    420    421    422    423  
img
DRAFT
TM 5-4210-249-13&P-2
0158
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 37.
Put circuit breaker 6 to OFF position, then put to ON position. Start hydraulic
generator (WP 0021). Put DRIVER FLOOD switch to ON position (WP 0004). Check if
circuit breaker 6 trips.
a.
If circuit breaker 6 trips, replace circuit breaker (WP 0360).
b.
If circuit breaker 6 does not trip, replace driver side extendable
floodlight (WP 0354).
TFFT04553
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 38.
Turn hydraulic generator off (WP 0021). Turn vehicle engine OFF (TM 9-2320-347-10).
Turn battery disconnect switch to OFF position (WP 0007). Remove cab instrument
panel A (WP 0311). Remove fuse FS 12 (WP 0401). Check for continuity across fuse
FS 12 terminal connectors.
If continuity is not present, replace fuse FS 12 (WP 0401).
0158-21