DRAFT
TM 5-4210-249-13&P-2
0151
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03676
Step 5.
Turn battery disconnect switch to OFF position (WP 0007). Turn Service Drive Lights
Off (TM 9-2320-347-10). Remove relay 19 from cab power distribution block
(WP 0402). Check for continuity across cab instrument panel wire harness wire 1624
(yellow) from cab power distribution block relay 19, terminal 2 to cab instrument panel
wire harness EMERG MASTER switch connector, terminal 5.
If there is continuity, replace EMERG MASTER switch (WP 0315).
0151-5