MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04313
Step 9.
Check for 22 to 28 VDC between wire 1687 (brown) from pump house cooling fan
temperature switch, terminal to a known good ground.
If 22 to 28 VDC are not present, troubleshoot Pump House Fan Does Not
Operate Properly (WP 0175).