TANK TO PUMP INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL) - Continued
TANK TO PUMP INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  206    207    208    209    210  211  212    213    214    215    216  
img
DRAFT
TM 5-4210-249-13&P-2
0143
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03746
Step 3.
Install lamp in pump operator's panel TANK TO PUMP indicator (WP 0327). Open
pump operator's panel housing (WP 0325). Check for continuity across pump
operator's panel wire harness wire 3895 (black) from pump operator's panel TANK TO
PUMP indicator to a known good ground.
If there is no continuity, repair wire 3895 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
0143-3