DRAFT
TM 5-4210-249-13&P-2
0127
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 21.
With a test lead set, check for continuity across sensor power wire from pump discharge
transducer wire harness connector, terminal B.
If continuity is not present, repair sensor ground wire in pump intake
replace pressure transducer wire harness (WP 0460).
Step 22.
digital pressure gauge wire harness connector. Turn battery disconnect switch to ON
position (WP 0007). With a test lead set, check for 22 to 28 VDC at pump intake
a.
If 22 to 28 VDC are present, replace pump intake pressure
transducer (WP 0411).
b.
If 22 to 28 VDC are not present, replace PUMP INTAKE digital
pressure gauge (WP 0317).
TFFT04359
Step 23.
Check if pump operator's panel PUMP DISCHARGE digital pressure gauge displays an
error message.
If pump operator's panel PUMP DISCHARGE digital pressure gauge does
not display an error message, go to Step 28.
0127-11