PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued
ROOF TURRET DOES NOT OPERATE WHEN SELECTED

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  894    895    896    897    898  899  900    901    902    903    904  
img
DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04162
Step 77.
Remove personnel cab instrument panel A (WP 0311). Remove circuit breaker 2 from
cab power distribution block (WP 0391). Check for continuity across circuit breaker.
a.
If continuity is present, replace cab power distribution wire harness and
block (WP 0441).
b.
If continuity is not present, replace circuit breaker 2 (WP 0391).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE