PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued
PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  892    893    894    895    896  897  898    899    900    901    902  
img
.
DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04164
Step 74.
Turn battery disconnect switch to OFF position (WP 0007). Remove 2 gauge cable
from primer pump motor ground terminal (WP 0262). Check for continuity across 2
gauge cable from primer pump motor 2 gauge ground cable termination to ground stud.
If continuity is not present, replace 2 gauge cable (WP 0393).
Step 75.
Install 2 gauge cable on primer pump motor ground terminal (WP 0262). Check for
continuity across ground jumperwire from primer pump motor ground terminal to primer
pump motor control solenoid.
If continuity is not present, repair or replace jumperwire
(TM 9-2320-325-14&P).
0115-46