DRAFT
TM 5-4210-249-13&P-1
0114
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03462
Step 31.
Disconnect main wire harness pump operator's panel wire harness connector DO1.
Disconnect main wire harness main 2 harness connector. With a test lead set, check
for continuity across main wire harness wire 4037 (orange) from main wire harness
pump operator's panel wire harness connector DO1, terminal H to main wire harness
main 2 wire harness connector, terminal 4.
a.
If there is continuity, repair wire 4037 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
b.
If there is no continuity, repair wire 4037 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
0114-21