BUMPER TURRET DOES NOT OPERATE PROPERLY WHEN SELECTED - Continued
BUMPER TURRET DOES NOT OPERATE PROPERLY WHEN SELECTED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  628    629    630    631    632  633  634    635    636    637    638  
img
. . .
DRAFT
TM 5-4210-249-13&P-1
0104
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02849
Step 19.
Put bumper turret control OSCILLATION switch to
(off) position (WP 0035). Operate
bumper turret control joystick in forward and rear positions (WP 0035), check if bumper
turret raises and lowers.
If bumper turret does not raise and lower, go to Step 39.
Step 20.
Operate bumper turret control joystick in forward and rear positions (WP 0035), check if
bumper turret raises and lowers at a rate suitable for system operations.
If bumper turret does not raise and lower at a rate suitable for system
operations, go to Step 61.