• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
WATER PUMP ENGINE CRANKS BUT WILL NOT START OR HARD TO START FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued
WATER PUMP ENGINE CRANKS BUT WILL NOT START OR HARD TO START FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  344    345    346    347    348  349  350    351    352    353    354  
img
DRAFT
TM 5-4210-249-13&P-1
0073
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04689
Step 7.
Remove EMR II inline fuse from pump operator's panel wire harness fuse holder
(WP 0394). Check for continuity across EMR II inline fuse terminal connectors.
If continuity is not present, replace EMR II inline fuse (WP 0394).
0073-6


Privacy Statement