TM 5-4210-233-14&P-1
5-14. STARTER REPAIR AND TESTING - Continued
(48)
Connect three field leads (81) to bush holders (14) with three screws (82).
(49)
Install gaskets (83) and inspection plugs (84).
e.
Follow-on Maintenance.
(1) Install starter (see para 5-12).
(2) Connect batteries (see para 4-114).
5-86
|