TM 5-4210-233-14&P-1 4-199.  AIR OPERATED AERIAL DISCHARGE VALVE - Continued (2) Remove four screws (19), two locating plates (20), retaining ring (21), gasket (22) and seat (23). Discard gasket. c. Cleaning and Inspection. WARNING Dry cleaning solvent P-D-680 is potentially dangerous.  Avoid repeated and prolonged breathing of vapors and skin contact with the liquid.  Do not use near open flame, arcing equipment or other ignition sources.  Always wear eye protection and protective clothing.  The flash point of P-D-680 is 100 to 138 deg. F (38 to 59 deg. C). (1) Clean all metal parts in dry cleaning solvent (Item 3, Appendix E). WARNING Death or serious injury could occur if compressed air is directed against the skin.  Do not use compressed air for cleaning or drying unless the pressure is/has been reduced to 30 psi (2.11 kg/cm2) or less.  When working with com- pressed air, always use chip guards, eye protection, and other personal protective equipment. (2) Dry all parts with compressed air. (3) Inspect  valve  body  (4),  seat  (23)  and  thrust  washer  (18)  for  damage.    Replace  parts  or  entire valve as necessary. d. Assembly. (1) Install  seat  (23),  new  gasket  (22),  and  retaining  ring  (21).    Install  two  locating  plates  (20)  and secure with four screws (19). (2) Install thrust washer (18), new gasket (17), cover (16) and secure with four lockwashers (15) and four screws (14). e. Installation. (1) Install valve (4), new gaskets (13), and elbow (12), and secure with eight bolts (11), eight nuts (10), and eight lockwashers (10A). (2) Slide seal (8) on pipe (9) and position between grooves in pipe (9) and elbow (12).  Use new seal if necessary. (3) Install two clamps (7) and secure with two bolts (6) and two nuts (5). (4) Install actuator (3) on valve (4) and secure with four washers (2) and nuts (1). f. Follow-on Maintenance. (1) Connect batteries (see para 4-114). 4-500

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business