TM 5-4210-233-14&P-1 4-22. PUMP PANEL TOGGLE SWITCHES This task covers: a. Inspection c. Follow-on Maintenance b. Replacement TOOLS REQUIRED EQUIPMENT CONDITION Tool Kit, General Mechanics, Automotive Main Engine Shutdown (see para.  2-12.) (Appendix B. Section III, Item 1) APU Shutdown (see para.  2-16.) Gauge Panel Removed (see para.  4-18.) MATERIALS/PARTS REQUIRED Batteries Disconnected (see para.  4-114.) Tags (Item 32, Appendix E) a. Removal. (1 )  Tag wires and remove screws (3). (2)   Remove nut (1) and lock washer (2). (3)   Remove switch (4). b. Installation. (1 )  Connect wires to switch with screws (3). (2)   Secure switch to panel with nut (1) and lock washer (2). c. Follow-on Maintenance. (1)   Install gauge panel (see para.  4-18). (2)   Connect batteries (see para.  4-114). (3)   Test operation of switch. 4-179