Click here to make tpub.com your Home Page

Page Title: Cleaning and Inspection-continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-4210-233-14&P-1
5-23. TURBOCHARGER-Continued
WARNING
Compressed air used for cleaning purposes shall not exceed 30
psi (207 kPa).  Use only with effective chip guarding and
personal protective equipment (goggles/shield, gloves, etc.).
(5)
Dry turbocharger parts with compressed air.
(6)
Inspect turbocharger parts for nicks, cuts, scratches, scoring or other damage.
(7)
Inspect screw threads for stripping or cross-threading.
NOTE
Measurements given in this section are for used parts.
(8) Check diameters of turbine wheel shaft journals (8 and 9) on
shaft (10) Journal diameters must be between 0.6250 and
0.6254-in (15.875 and 15.885 mm).
(9) Inside diameter of compressor wheel (11) must not be greater than
0.3749-in (9.522 mm).
(10) Inside diameter of center housing (12) must not be greater
than 0.9842-in (24.998 mm).
5-152

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business